Why is FLU-ACE™ more efficient than a typical feedwater economiser?

Thermal Energy International

Dec 2015

Why is FLU-ACE™ more efficient than a typical feedwater economiser? image
FLU-ACE uses direct contact gas-to-liquid mass transfer and heat exchange. It condenses almost all of the water vapour (steam) from the exhaust, and this latent heat is the source of the bulk of the waste heat available in a boiler flue gas.  
 
“Sensible” heat refers to energy that can be released through a temperature change.  Heating water from 32°F to 212°F (0°C to 100°C) is a change in “sensible” heat.  “Latent” heat refers to energy stored or released in a phase change, such as the heating that is done when steam changes from vapor to water, without any temperature change.  As it turns out, the energy released when a pound of steam turns into a pound of water, all happening at 212°F (100°C) (no temperature change, so this is latent heat) is some five times the energy released when that same pound of water is cooled from 212°F to 32°F (100°C to 0°C).  All this to say there is a lot of energy released in the phase change from water vapor to liquid water.  

Therefore, condensing heat recovery technology, which can capture latent heat, is much more efficient than the typical feedwater economizer, which can only capture sensible heat. When it comes to overall boiler plant efficiency, FLU-ACE is able to provide a 10% to 15% improvement, while a typical feedwater economizer provides an improvement of 2% to 4%.

Sustainability that pays for itself

Proven solutions that deliver verified returns from day one.

Speak to our team

If you are exploring how to cut energy use, reduce emissions or assess the viability of steam, heat recovery or hot water solutions for your site, our team can help you understand what is possible. 

  • Identify where energy is being lost
  • Understand the most effective efficiency improvements for your site
  • Gain clear guidance on performance expectations and practical implementation